• What can you cook from squid: quick and tasty

    General industrial type pressure transmittersMBS 3000

    The compact pressure sensor type MBS 3000 is designed for use in almost all types of industrial equipment and provides reliable pressure measurement even in the most adverse conditions
    exploitation. The compact pressure transmitter type MBS 3050 for heavy duty applications with built-in pulsation damper is intended for use in hydraulic systems with
    harsh conditions of the working environment (cavitation, water hammer, sudden pressure surges) and provides reliable pressure measurement even in the most adverse operating conditions.
    Wide, flexible range of pressure transmitters provide output signals of various types and measurement of absolute and gauge (relative) pressure in the ranges from 0 - 1 to 0 - 600 bar. There is a wide range of process connection options and electrical connection... Exceptional vibration resistance, robust construction, high degree EMC and EMI protection ensure that pressure transmitters meet the most stringent industrial requirements.

    Characteristics

    For industrial equipment and heavy duty hydraulic systems
    High resistance to cavitation, water hammer and sudden pressure surges (MBS 3050)
    The body and parts in contact with the working medium are made of acid-resistant of stainless steel(AISI 316L)
    Measuring ranges of relative (gauge) and absolute pressures from 0 to 600 bar
    Full range of standard output signals: 4 - 20 mA, 0 - 5 V, 1 - 5 V, 1 - 6 V, 0 - 10 V, 1 - 10 V
    Wide choose process connection and electrical connection options
    Temperature compensation and laser calibration

    Operating and working environment conditions for MBS 3050 sensors

    Operating conditions
    Changes in the flow rate of the working fluid in hydraulic systems, for example, when quickly closing valves or starting and stopping pumps, can cause cavitation, water hammer and sudden pressure surges.
    These phenomena can occur both at the inlet and at the outlet of the sensor even at relatively low operating pressures.

    Working environment conditions
    The presence of contaminants in the fluid can clog the nozzle orifice. Installing the sensor in a strictly vertical position allows
    minimize the risk of clogging. The viscosity of the working medium does not significantly affect the reaction time. Even with viscosities up to 100 cSt, the response time will not exceed 4 ms.

    Specifications

    Measurement uncertainty (including non-linearity, hysteresis and repeatability) ≤ ± 0.5% of measuring range
    BFSL nonlinearity (max.discrepancy) ≤ ± 0.2% of measuring range
    Hysteresis and repeatability ≤ ± 0.1% of measuring range
    Influence of temperature on the zero reference position
    Influence of temperature on the measuring range ≤ ± 0.1% of measuring range / 10K
    Reaction time With the viscosity of the working fluid
    Air and gases (MBS 3050)
    Overload pressure (static) 6x upper limit of measurement (max. 1500 bar)
    Burst pressure 6x upper limit of measurement (max. 2000 bar)
    Resource, at pressures of 10 - 90% of the upper measurement limit > 10 × 106 cycles


    Nominal output signal
    (short-circuit protected)
    4 - 20 mA 0 – 5, 1 – 5,
    1–6 V
    0 - 10 V, 1 - 10 V
    Supply voltage (U supply), with reverse polarity protection 9 - 32V 9 - 30V 15 - 30V
    Power consumption ≤ 5mA ≤ 8mA
    ≤ ± 0.1% of the upper limit of measurement at 10 V
    Max. permissible current 28 mA (typical)
    Load resistance (R N) (relative to power supply zero) R n ≥ 10 kOhm R n ≥ 15 kΩ

    Operating conditions
    Sensor operating temperature range Standard Application -40 - 85 ° C
    Working medium temperature range 115 - (0.35 × temperature value environment)
    Ambient temperature range
    (depending on the type of electrical connection)
    See page 6
    0 - 80 ° C
    Transport / storage temperature range -50 - 85 ° C
    EMC (radiation) EN 61000-6-3
    EN 61000-6-2
    Insulation resistance > 100 MOhm at 100 V
    Testing increased voltage increased frequency According to SEN 361503
    Vibration resistance Sinusoidal vibration 15.9 mm-pp, 5 Hz - 25 Hz IEC 60068-2-6
    20 g, 25 Hz - 2 kHz
    Random vibration 7.5 g rms , 5 Hz - 1 kHz IEC 60068-2-64
    Shock resistance Hit 500 g for 1 ms IEC 60068-2-27
    Free fall 1m IEC 60068-2-32
    Enclosure protection class (depending on the type of electrical connection)

    Mechanical characteristics

    Order codes

    Pressure transmitters for heavy dutyoperating conditions type MBS 3200

    Compact high temperature transmitter pressure MBS 3200 is intended for use in hydraulic systems and virtually all industries. The converter provides reliable
    pressure measurement even in harsh environmental conditions. Converter MBS 3250 with built-in pulsation damper is intended for use in hydraulic systems with intensive
    operating fluid influences such as cavitation, water hammer or pressure surges. The transmitter provides reliable pressure measurement even in harsh environmental conditions. A wide, flexible range of pressure transmitters provides various types of output signals and measurement of absolute and gauge (relative) pressure in the range from 0 - 1 to 0 - 600 bar and a wide range of process and electrical connection options. Robust design, excellent vibration resistance, as well as a high degree of electromagnetic compatibility and protection against electromagnetic
    transducer emissions ensure compliance with the most stringent requirements for industrial applications.

    Advantages

    • Designed for use in harsh industrial and hydraulic systems.
    • Working and ambient temperatures up to 125 ° C.
    • Built-in pulsation damper. Protection against cavitation, water hammer or pressure surges (MBS 3250).
    • Full range of standard output signals: 4 - 20 mA, 0 - 5 V, 1 - 5 V, 1 - 6 V, 0 - 10 V, 1 - 10 V.
    • The body and parts in contact with the working medium are made of stainless steel AISI 316L.
    • Wide range of process and electrical connection options.
    • Temperature compensation, linearized, laser calibrated.
    Technicalspecifications

    Performance characteristics (EN 60770)

    Accuracy (including non-linearity, hysteresis and repeatability) ≤ ± 0.5% of measuring range
    BFSL non-linearity (match) ≤ ± 0.2% of measuring range
    Hysteresis and repeatability ≤ ± 0.1% of measuring range
    Temperature error range (compensated temperature range) ≤ ± 1.0% of measuring range
    Fluids with viscosity
    Air and gases (MBS 3250)
    Overload pressure (static) 6x measuring range (max. 1500 bar)
    Burst pressure 6x measuring range (max. 2000 bar)
    Resource, at pressures of 10 - 90% of the measuring range > 10 × 10 6 cycles

    Electrical characteristics
    Rated output signal (short-circuit protected) 4 - 20 mA 0 - 5, 1 - 5, 1 - 6 V
    fast. current
    0 - 10 V, 1 - 10 V DC
    current
    Supply voltage, reverse polarity protected 9 - 32 VDC current 10 - 30 V DC current 15 - 30 VDC current
    Power consumption ≤ 5mA ≤ 8mA
    Influence of supply voltage on measurement error ≤ ± 0.1% of measuring range / 10 V
    Max. permissible current 28 mA (typical)
    Output impedance ≥ 25 kΩ
    R n ≤ (U pit. - 9 V) / 0.02 A R n ≥ 10 kOhm R n ≥ 15 kΩ

    Operating conditions
    Sensor temperature range (depends on gasket material) Standard Application -40 - 125 ° C
    Max. working environment temperature 165 - (0.35 × ambient temperature)
    Ambient temperature range (depending on the type electrical connection) See page 5
    Compensated temperature range 0 - 100 ° C
    Transport / storage temperature range -50 - 125 ° C
    EMC (radiation) EN 61000-6-3
    EMC (protection against electromagnetic radiation) EN 61000-6-2
    Insulation resistance > 100 mΩ at 100 VDC current
    Power frequency voltage test SEN 361503
    Vibration resistance Sinusoidal impact 5 - 25 Hz amplitude 15.9 mm-pp IEC 60068-2-6
    25 Hz - 2 kHz with 20 g acceleration
    Accidental exposure 5 Hz - 1 kHz @ 7.5 g rms IEC 60068-2-64
    Shock resistance On blows 500 g / 1 ms IEC 60068-2-27
    Free fall 1m IEC 60068-2-32
    Enclosure protection class (depending on the type of electrical connection)

    Mechanical characteristics

    Compact pressure transducer MBS 3000, Designed for use in almost all industrial areas, it provides reliable pressure measurement even in harsh environmental conditions.
    The wide range of pressure transmitters provides 4-20 mA current output, absolute or gauge pressure measurement, various measuring ranges from 0-1 to 0-600 bar, various options for connecting pressure impulse lines and electrical connections.
    Excellent vibration resistance, rugged construction, and high EMC and RFI protection ensure compliance MBS 3000 the most stringent requirements for industrial installations.

    • Output signal 4 - 20 mA
    • Operating temperature -40 to 85 ° C
    • Measuring range 0 - 600 bar
    • Standard pressure connection, G 1 / 4A ISO 228/1
    • For industrial use in harsh environments such as pumps, compressors, pneumatic systems and water treatment plants

    Special features of the MBS3000

    For Industrial Equipment and Heavy Duty Hydraulic Systems /

    The body and parts in contact with the medium are made of acid-resistant stainless steel (AISI 316L)

    Measuring ranges of relative (gauge) and absolute pressures from 0 to 600 bar

    Full range of standard output signals: 4 - 20 mA, 0 - 5 V, 1 - 5 V, 1 - 6 V, 0 - 10 V, 1 - 10 V

    Wide range of process and electrical connection options

    Temperature compensation and laser calibration y For hazardous areas of class 2.

    Operating conditions MBS3000

    Changes in the flow rate of the working fluid in hydraulic systems, for example, when quickly closing valves or starting and stopping pumps, can cause cavitation, water hammer and sudden pressure surges. These phenomena can occur both at the inlet and at the outlet of the sensor even at relatively low operating pressures.

    Working environment conditions MBS 3000.

    The presence of contaminants in the fluid can clog the nozzle orifice. Installing the sensor in a strictly vertical position minimizes the risk of clogging. The viscosity of the working medium does not significantly affect the reaction time. Even with viscosities up to 100 cSt, the response time will not exceed 4 ms.

    MBS3000 Ordering Scheme

    The main modifications of MBS 3000 available for order in our company:

    vendor code

    Order code

    Short description

    060G1113

    MBS 3000-1011-1AB04

    Output: 4-20mA

    Range start, bar: 0.0

    End range, bar: 1

    Connection: G 1/4

    060G1429

    MBS 3000-1211-1AB04

    Output: 4-20mA

    Range start, bar: 0.0

    End range, bar: 1.6

    Connection: G 1/4

    060G1122

    MBS 3000-1411-1AB04

    Output: 4-20mA

    Range start, bar: 0.0

    End range, bar: 2.5

    Connection: G 1/4

    060G1123

    MBS 3000-1611-1AB04

    Output: 4-20mA

    Range start, bar: 0.0

    End range, bar: 4

    Connection: G 1/4

    060G3812

    MBS3000-1615-1AB04

    Output: 0-10V

    Range start, bar: 0.0

    End range, bar: 4

    Connection: G 1/4

    060G1101

    MBS 3000-1811-1AB04

    Output: 4-20mA

    Range start, bar: 0.0

    End range, bar: 6

    Connection: G 1/4

    060G1414

    MBS3000-1811-1AB08

    Output: 4-20mA

    Range start, bar: 0.0

    End range, bar: 6

    Connection: G 1/2

    060G1125

    MBS 3000-2011-1AB04

    Output: 4-20mA

    Range start, bar: 0.0

    End range, bar: 10

    Connection: G 1/4

    060G1650

    MBS 3000-2015-1AB04

    Output: 0-10V

    Range start, bar: 0.0

    End range, bar: 10

    Connection: G 1/4

    060G1133

    MBS 3000-2211-1AB04

    Output: 4-20mA

    Range start, bar: 0.0

    End range, bar: 16

    Connection: G 1/4

    060G3813

    MBS3000-2215-1AB04